Vane pump Parker T6CCM-B25-B10-3R02-D111
- Article no:
- 78232164
Comparison number:
02464234002|024-64234-002|78080163|T6CCMB25B103R02D111
Name | Value |
---|---|
P2 Drive power P (kW) at n=1500 min-1 - p=7 bar | 1.7 kw |
Manufacturer/article number | Parker T6CCM-B25-B10-3R02-D111 |
P2 Drive power P (kW) at n=1500 min-1 - p=140 bar | 13.4 kw |
P2 Flow rate Q (l/min) at n=1500 min-1 - p=140 bar | 45.7 l/min |
P2 Drive power P (kW) at n=1500 min-1 - p=240 bar | 22.3 kw |
Shaft type | Splined shaft with involute flanks (SAE B) |
P2 Flow rate Q (l/min) at n=1500 min-1 - p=240 bar | 41.2 l/min |
Classification | Hydraulics - Vane pumps Special versions |
P1 Flow rate Q (l/min) at n=1500 min-1 - p=240 bar | 109.0 l/min |
Lifting ring stage 2 Vgmax | 34.1 cm³/rev |
P1 Drive power P (kW) at n=1500 min-1 - p=7 bar | 2.5 kW |
P1 Flow rate Q (l/min) at n=1500 min-1 - p=0 bar | 118.9 l/min |
P2 Flow rate Q (l/min) at n=1500 min-1 - p=0 bar | 51.1 l/min |
P1 Drive power P (kW) at n=1500 min-1 - p=240 bar | 49.5 kw |
Lifting ring stage 1 Vgmax | 79.3 cm³/rev |
Position of the connections | 02 |
P1 Drive power P (kW) at n=1500 min-1 - p=140 bar | 29.2 kW |
Suction connection S | 2"1/2 |
Pressure connection P1 | 1" |
Pressure connection P2 | 3/4" |
Series | T6CCM Mobile version with 1 shaft seal |
Direction of rotation | Clockwise rotation |
Flange | SAE flange (J518c) |
Execution letter | D |
Thread | UNC thread |
Gasket | BUNA N (nitrile rubber) |
P1 Flow rate Q (l/min) at n=1500 min-1 - p=140 bar | 113.5 l/min |