Classification |
Hydraulics - Parker triple pump-T7EDB/T7EDBS |
P2 Drive power P (kW) at n=1500 min-1 - p=7 bar |
2.2 kw |
Direction of rotation |
Clockwise rotation |
P2 Flow rate Q (l/min) at n=1500 min-1 - p=0 bar |
121.7 l/min |
P2 Flow rate Q (l/min) at n=1500 min-1 - p=250 bar |
109.9 l/min |
Pressure connection P1 |
1"1/2 |
Lifting ring stage 2 Vgmax |
81.1 cm³/rev |
Flange |
SAE four-hole flange (J518) |
Lifting ring stage 1 Vgmax |
227.1 cm³/rev |
P1 Drive power P (kW) at n=1500 min-1 - p=7 bar |
6.9 kW |
P1 Flow rate Q (l/min) at n=1500 min-1 - p=140 bar |
330.6 l/min |
P3 Flow rate Q (l/min) at n=1500 min-1 - p=140 bar |
65.8 l/min |
Pressure connection P2 |
1"1/4 |
Gasket |
BUNA N (nitrile rubber) |
P3 Flow rate Q (l/min) at n=1500 min-1 - p=0 bar |
67.5 l/min |
P2 Drive power P (kW) at n=1500 min-1 - p=140 bar |
29.5 kw |
Manufacturer/article number |
Parker T7EDBS-072-B24-B14-2R00-A1M1 |
Position of the connections |
00 |
P1 Drive power P (kW) at n=1500 min-1 - p=140 bar |
82.6 kW |
P2 Flow rate Q (l/min) at n=1500 min-1 - p=140 bar |
115.0 l/min |
P3 Drive power P (kW) at n=1500 min-1 - p=140 bar |
16.3 kw |
P3 Drive power P (kW) at n=1500 min-1 - p=300 bar |
34.5 kw |
Suction connection S |
4" |
Lifting ring stage 3 Vgmax |
45.0 cm³/rev |
P3 Flow rate Q (l/min) at n=1500 min-1 - p=300 bar |
63.9 l/min |
P2 Drive power P (kW) at n=1500 min-1 - p=250 bar |
52.1 kw |
P1 Flow rate Q (l/min) at n=1500 min-1 - p=240 bar |
323.5 l/min |
Pressure connection P3 |
3/4" |
P3 Drive power P (kW) at n=1500 min-1 - p=7 bar |
1.2 kw |
Series |
T7EDBS - 4-hole flange according to SAE E, J744 |
Thread |
Metric thread |
P1 Flow rate Q (l/min) at n=1500 min-1 - p=0 bar |
340.6 l/min |
Shaft type |
Parallel key shaft (SAE D & E) |
Execution letter |
A |
P1 Drive power P (kW) at n=1500 min-1 - p=240 bar |
139.5 kw |